Tuesday, October 18, 2011

GOST 8045-82 Outdoor lighting. General specifications

GOST 8045-82 UDC 628.971.6:006.354 Group E83 INTERSTATE STANDARD Outdoor lighting General specifications Luminaires intended for outdoor use. General specifications MKC 29.140.40 OKP 34 6120 Effective date 01.01.1984 MEDIA INFORMATION 1. Developed and submitted by the Ministry of Electrical Industry of the USSR 2. Approved and put into effect by Decision of the USSR State Committee on Standards of 06.10.82 № 3898 3. The standard is fully consistent ST SEV 172-84 4. The standard has introduced the international standard IEC 598-2-3-79 with Amendment number 1 (1983) 5. INSTEAD GOST 8045-75 6. REFERENCE normative and technical documents Designation NTD, which was referenced paragraph number GOST 2.601-95 1.2 9.039-74 GOST GOST 01/04/1917 12.2.007.0-75 1.3.1 GOST 2746-90 GOST 7377-85 01/04/1914 05.02 GOST 8828 - 89 5.2 GOST 9806-90 GOST 10036-75 01.04.1914 1.2.7 GOST 14254-96 1.2.6; 1.4.2 01/05 15150-69 1.4.1, 01/04/1913; 5.1 5.2 GOST 16962-71 1.4. 9, 01.04.1910, 02.04 GOST 17516-72 GOST 17677-82 1.4.3 Chapeau, 1.2.1, 1.2.3, 2.1, 3.1, 4.1, 5.1, 6.1 GOST 18396-88 GOST 18620-86 04/01/1914 05.01 GOST 23216-78 GOST 24671-84 05.02 01/04/1918 GOST 26092-84 GOST 27682-88 01.04.1921 1.4.1 7. Limitations on the duration from the protocol № 3-93 of the Interstate Council for Standardization, Metrology and Certification (ISC 05.06.1993) 8. PUBLICATION (December 2002) with Amendments number 1, 2, 3, approved in October 1985 and October 1987, June 1988 (ICS 1-86, 12-87, 9-88) This standard applies to Outdoor lighting with incandescent lamps or gas discharge lamps that are intended for street lighting, roads, squares, traffic tunnels and flyovers, pedestrian crossings, open spaces for production purposes, as well as functional and decorative lighting squares, parks and boulevards, which are produced by the economy and exports. The standard does not apply to fittings for vehicles, explosion (miner) and explosion-proof fixtures. Fixtures must meet the requirements of GOST 17677 and the requirements set forth in the relevant sections of this standard. (Revised edition, Alt. № 1, 3). 1. SPECIFICATIONS 1.1. Fixtures shall be made in accordance with the requirements of this standard and technical specifications for specific types of lamps or groups of technical documentation, duly approved. 1.2. Lighting Requirements 1.2.1. Curves of intensity lights in a vertical plane should correspond to GOST 17677, in the horizontal - Annex 2 and should be made in the technical specifications for specific types of lamps or groups. (Revised edition, Alt. № 2). 1.2.2. Intensity of the light fixtures for street lighting, roads, squares, with a wide and polushirokoy curve of intensity with a conditional lamp, luminous flux which is equal to 1000 lumens in the zone of angles a = 75 ° - 90 ° from vertical in the main transverse plane should be no more than specified in Table. 1. Table 1: a force of light, candles, no more for discharge lamps with brushed flask and incandescent lamps for discharge lamps with a transparent bulb 75 ° 80 ° 200 200 80 50 85 15 90 ° 25 ° 20 10 (Revised edition, Alt. № 1) . 1.2.3. Maximum utilization of the light flux for illumination and the maximum gain of lamps for street lighting, roads and plazas shall be as specified in Table. 2. (Revised edition, Alt. № 2). 1.2.4. The coefficient of luminous flux of light in a horizontal or vertical depending on the purpose and scope of functional and decorative lighting fixtures lighting squares, parks and boulevards should be specified in the technical specifications for lighting of specific types or groups. 1.2.5. Gain of the lamps for lighting of open spaces for production purposes must be at least 10. 1.2.6. The efficiency of the lamps shall not be less than indicated in the table. 3. 1.2.7. Transmittance prelomlyateley in a zone free of prisms, as well as protective glazing should be no lower than 0.85, and the lens - in accordance with GOST 10036. 1.2.8. Specular reflectors, or paste should be an integral reflection coefficient not lower than 0.80, and diffuse - not lower than 0,75. 1.2.9. Reflectance and transmittance of optical elements of the system should not vary by more than 5% after 500 h of lights in operation. 1.3. Electrical requirements 1.3.1. Fixtures shall be made protection classes I, II or III according to GOST 12.2.007.0. Particular class of security lights should be specified in the technical specifications for lighting of specific types or groups. (Revised edition, Alt. № 1). 1.3.2. For grounding metal parts netokoveduschih lamp must have a protective clip with a screw diameter of at least 6 mm. 1.3.3. 1.3.4. (Deleted, Mod. № 2). Table 2 Curve type of intensity in the horizontal plane of the type of the curve of intensity in the vertical plane in accordance with GOST 17677

No comments:

Post a Comment