GOST 50571.11-96 Electrical installations of buildings. Part 7. Requirements for special installations. Bathrooms and shower rooms

GOST 50571.11-96 (IEC 364-7-701-84) UDC 696.6:006.354 Group E08 STATE STANDARD OF THE RUSSIAN FEDERATION Electrical installations of buildings Part 7: Requirements for special installations Section 701 BATHROOM AND SHOWER ROOM Electrical installations of buildings. Part 7. Requirements for special installations or locations. Section 701. Locations containing a bath tub or shower basin ACS 27020, 29020 OKS 3402 Date vvedeniya1997-01-01 Preface 1. Prepared and submitted to the Technical Committee for Standardization TC 337 "Electrical residential and public buildings." 2. Adopted and put into operation the Decree of the State Standard of Russia July 10, 1996 № 446. 3. This standard is the authentic text of the international standard IEC 364-7-701-84 "Electrical installations of buildings. Part 7. Requirements for special installations. Section 701. Bathrooms and shower rooms. 4. First introduced. Introduction This standard is included in Part 7 of the State's standards for electrical installations of buildings developed on the basis of the standards of the International Electrotechnical Commission IEC 364 "Electrical installations of buildings", regulating the requirements for the safe operation of electrical installations of buildings. Numbering sections and paragraphs in standard corresponds to the numbering adopted in IEC 364-7-701-84. Requirements of the standard complement, modify or supersede the requirements of individual state standards set 30331/GOST GOST R 50571 on electrical installations of buildings, as reflected in the notation of sections and paragraphs of the standard. For example: 701.411.1.4.3 - designation of item, which changes the requirements of GOST 411.1.4.3 30331.3-95/GOST P 50571.3-94. In addition, for electrical installations of bathrooms and shower rooms shall apply the requirements of other standards set 30331/GOST GOST R 50571 as it pertains to these installations or locations. 1. Scope This standard establishes special requirements for electrical installations in bathrooms and shower facilities in the surrounding areas, where there is an increased risk of electrical shock people. General safety requirements - according to GOST R 50571.1 30331.1/GOST (Part 2). These requirements do not apply to a private shower stall, prefabricated with your shower tray and drain, with the exception of 701.53b. Note. Bathroom facilities, for medical purposes, you may need special requirements. 2. Statutory references in this standard references to the following standards: GOST 7397.0-89. Switches for household and similar fixed electrical installations. General specifications. GOST 30331.1-95 (IEC 364-1-72, IEC 364-2-70) / GOST 50571.1-93 (IEC 364-1-72, IEC 364-2-70) Electrical installations of buildings. Key provisions of GOST 30331.3-95 (IEC 364-4-41-92) GOST 50571.3-94 (IEC 364-4-41-92) Electrical installations of buildings. Part 4. Security requirements. Protection against electric shock, 701. BATHROOM AND SHOWER ROOM. 701.3. Common characteristics. 701.32. Classification of zones. The requirements of this standard to ensure safety and choice of electrical equipment based on the following scale zones of bathroom and shower facilities (see 701A and 701V). Zone 0 is the inner volume of the bath or shower. Zone 1 is limited to: the outer vertical plane of the bath or shower, or a vertical plane at a distance of 0,60 m from the shower spray - for a shower without a shower tray, floor and the horizontal plane at a distance of 2,25 m above the floor. Zone 2 is limited to: the outer vertical plane of zone 1 and the parallel vertical plane at a distance of 0.60 m floor to a horizontal plane at a distance of 2,25 m above the floor. Zone 3 is limited to: the outer vertical plane of zone 2 and the parallel vertical plane at a distance of 2.40 m floor to a horizontal plane above the floor at a distance of 2,25 m. The dimensions are measured in the light walls and fixed partitions (Figures 701A and 701V). 701.4. Security requirements. 701.41. Protection against electric shock. Note. Protect outlets - for 701.53a of this standard. 701.411.1.4.3. When applied as a protective measure of BSNN protection from immediate direct contact with live parts, regardless of the rated voltage, should be done: a fence, or shells, which ensure at least a degree of protection of at least IR2H, or insulation capable of withstanding a test voltage AC 500 V (rms) for 1 min. 701.413.1.6. Equipotential bonding. The system of additional potential equalization must be attached as any number of conductive parts, all exposed conductive parts in zones 1, 2 and 3, as well as all protective conductors. 701,471. Application of protective measures against electric shock. 701.471.0. In the zone 0 is allowed only with the use of protection systems BSNN ZSNN or at a nominal voltage not exceeding 12V, and the power supply system BSNN or ZSNN should be located outside the zone 0. 701.471.1. Not allowed protection through barriers (412.3 30331.3/GOST GOST R 50571.3) and the placing out of reach (412.4 30331.3/GOST GOST R 50571.3). 701.47.1.2. Not allowed protection by placing electrical equipment in a non-conductive areas (413.3 30331.3/GOST GOST R 50571.3) and the use of local bonding without the ground (413.4). 701.5. Selection and installation of electrical equipment. 701.51. General rules. 701.512.2. Electrical equipment should have at least the following level of protection: in the zone 0 - IRH7; Zone 1 - IRH5; Zone 2 - IRH4 (IRH5 - in the public baths) in zone 3 - IRH1 (IRH5 - in the public baths). 701.52. Wiring. 701.520.01. The requirements apply to the open wiring and concealed wiring (the depth of no more than 5 cm). 701.520.02. Wiring must have insulation that meets the requirements of 413.2 GOST30331.3/GOST P 50571.3, without any metal shell. Note. Such wiring may consist, for example, from single-core cables in an insulating sheath or multicore cables with an insulating sheath. 701.520.03. In zones 0, 1 and 2 should be only the wiring needed to power devices in these zones. 701.520.04. Junction boxes are not installed in zone 0, 1 and 2. 701.53. Distribution and control devices. a) In zones 0, 1 and 2, distribution and control devices are not installed. Note. Switches, actuated by the cord can be installed in Zones 1 and 2, provided that they comply with the requirements of GOST 7397.0. In zone 3 sockets can be installed if they are: individual or connected to separating the transformer in accordance with 413.5.1 30331.3/GOST GOST R 50571.3, or connected to a power supply system BSNN or ZSNN to 411.1 30331.3/GOST GOST R 50571.3, or protected by residual current device, which is responsive to differential current not exceeding 30 mA. b) All switches and sockets should be at least 0,60 m from the door in the shower stall, prefabricated (Figure 701S). 701.55. Other stationary electrical equipment. These requirements do not apply to electrical appliances if they are connected to a power supply system BSNN in accordance with the requirements of 411.1, 411.1.4.3 30331.3/GOST GOST R 50571.3, or the power supply system according ZSNN 411.1, 411.1.5.1, 411.1.5.2 GOST 30331.3 / GOST 50571.3. In the zone 0 shall be permitted only appliances designed for use in the bath. In Zone 1 can only be mounted heaters. In zone 2 can only be installed water heaters and lighting class II. Heating elements, laying in the floor and used for space heating can be installed in all zones provided that they are covered with metal mesh or a grounded metal sheath connected to the system of bonding, the technical requirements which are specified in 701.413.1.6. 1-and 2-b 7-c 11-d 8-f 9-f Figure 701A - Sizes zones (map) 1-a - a bath, 2-b - bath with a stationary barrier, 3 - Zone 0, 4 - Zone 1 5 - Zone 2, 6 - Zone 3, 7 th - shower pan, 8-e - free shower pan, 9-f - free shower pan, but with a stationary barrier, 10 - sprinkler shower, 11-d - shower tray with a stationary barrier 1-g 6-h 7-i Figure 701V - Dimensions zones (vertical section) 1-g - bath, 2 - Zone 1, 3 - Zone 2, 4 - Zone 3, 5 - Zone 0, 6 - h - shower tray, 7-i - free shower pan, but with a stationary barrier, 8 - a stationary wall-partition Figure 701 C - Location of the shower (DC), prefabricated Keywords: electrical buildings; bath room, shower room ; adjustment capabilities; wiring, selection of electrical equipment, installation of electrical Published 20/07/2008 State Standards on the topic "Electrical, lighting, security systems," GOST 15597-82 Fixtures for industrial buildings. General specifications GOST 2.702-75 Unified system for design documentation. Rules for making electronic circuits with GOST 2.752-71 Unified system for design documentation. Graphical symbols in diagrams. Robot device GOST 2.755-87 Unified system for design documentation. Graphical symbols in electrical circuits. Device switching and contact connections GOST 2.756-76 * Unified system for design documentation. Graphical symbols in diagrams. Is often perceived electromechanical devices GOST 2.757-81 * Unified system for design documentation. Graphical symbols in diagrams. Elements of the switching field for switching systems GOST 2.758-81 Unified system for design documentation. Graphical symbols in diagrams. Signal Technology GOST 2.762-85 * Unified system for design documentation. Graphical symbols in electrical circuits. Frequencies and frequency bands for transmission systems GOST 2.763-85 * Unified system for design documentation. Graphical symbols in electrical circuits. Device with a pulse-code modulation GOST 2.764-86 Unified system for design documentation. Graphical symbols in electrical circuits. Integrated optoelectronic display elements GOST 2.768-90 Unified system for design documentation. Graphical symbols in diagrams.

No comments:

Post a Comment