GOST 23274-84 UDC 728.7:006.354 Group ZH20 INTERSTATE STANDARD BUILDINGS mobile (inventory) ELECTRICAL General specifications Mobile buildings. Electrical devices. General specifications OKP 536,300 Effective date 01.07.1984 MEDIA INFORMATION 1. Developed by the Ministry of electrotechnical industry, Central Research and Design-Experimental Institute organization, mechanization and technical assistance to build (TSNIIOMTP) USSR State Construction, Leningrad zonal research and design institute model and experimental design of residential and public buildings (LenZNIIEP) Gosgrazhdanstroya, Central Research Research and design institute of experimental engineering equipment (TSNIIEP engineering equipment) Gosgrazhdanstroya. INTRODUCED by the Ministry of Electricity Industry 2. Approved and put into effect by Decision of the USSR State Committee for Construction of 22.12.83 № 327 3. INSTEAD GOST 23274-78 4. REFERENCE normative and technical documents Designation NTD, which was referenced paragraph number GOST 2.601-95 GOST 12.2.007.0-75 3.2 1.6.7 1.6.7 12.2.007.1-75 GOST GOST GOST 12.2.007.3 12.2.007.2-75 1.6.7 -75 12.2.007.4-75 1.6.7 1.6.7 GOST GOST GOST 12.2.007.6-75 12.2.007.5-75 1.6.7 1.6.7 1.6.7 GOST GOST 12.2.007.8-75 12.2.007.9-93 1.6.7 GOST GOST 12.2.007.9.8-89 12.2.007.9.1-95 1.6.7 1.6.7 1.6.7 12.2.007.10-87 GOST GOST GOST 12.2.007.12-88 12.2.007.11-75 1.6.7 1.6.7 Standard 12.2.007.13-2000 1.6.7 Standard GOST 3262-75 12.2.007.14-75 1.6.7 1.5.6 1.2.2 GOST 13109-97 GOST 14192-96 GOST 14254-96 4.2 1.1.4 1.2.9 GOST 15150 - 69 1.1.3, 1.2.9, 4.1, GOST 15543-70 GOST 15846-79 1.1.3 4.1 1.1.3 GOST 15963-79 GOST 16556-81 GOST 17412-72 1.6.4 1.1.3 GOST 18690-82 GOST 22853 01.04 -86 Chapeau, 1.3.5, 1.4.9, 5. PUBLICATION (November 2001) with Amendment number 1, approved in December 1989 (MIS 9-90) This standard applies to electrical mobile (inventory) of buildings (hereinafter - the building) of all types in accordance with GOST 22853 and establishes common technical requirements for Rules of acceptance, as well as information on design, operation, installation (dismantling), labeling, transport and storage. (Revised edition, Alt. № 1). 1. SPECIFICATIONS 1.1. General Requirements 1.1.1. Electrical installations should be constructed in accordance with the requirements of this standard, standards or technical specifications for building specific types of documentation, duly approved. 1.1.2. Electrical installations, other than the requirements of this standard should meet the requirements of the Rules for Electrical and Regulations for the Operation of electric consumers, the Energy Ministry approved the USSR. 1.1.3. Electrical installations under the terms of their operation in certain climate areas must meet the requirements of GOST 15150, GOST 15963, GOST 17412 and GOST 15543. 1.1.4. The degree of protection of environments of electrical products used in buildings, depending on their operating conditions, should comply with GOST 14254. 1.1.5. Electrical installations must comply with species and variety of buildings, located in convenient and accessible to service locations have secure attachment to the building designs and operations must be electrical, but when it is required by the conditions of production, - fire and explosion. 1.1.6. Electrical supply to the consumer should be in sets. The kit is installed in the working documentation for building a particular type. The kit includes electrical products, before the transportation of dismantled buildings (in accordance with Clause 3.1) must be included in a pick list of the building. 1.1.7. In the working drawings, building constructions should be provided for fixtures for mounting electrical elements in those places where you can not make attachment to the load-bearing frame of the building. 1.1.8. Structure and mode of attachment of electrical installations, are not subject to demolition in preparation for the relocation of buildings of container and block-containers in accordance with paragraph 3.1, should provide the stability of these devices to vibration during the movement of buildings. Design and methods of fixing electrical, dismantled in relocation of buildings, should be provided with the convenience and ease of assembly and disassembly. 1.2. Requirements for power supply and connection to a power source of electricity 1.2.1. Electrical installations of buildings should be designed for connection to the mains voltage of 380-220 V, 50 Hz with earthed neutral. Electrical, plug into an electrical network having voltage and (or) frequency than that specified, supply of technical specifications for building a particular type. 1.2.2. Voltage deviation from the nominal power consumers - according to GOST 13109. 1.2.3.
No comments:
Post a Comment