GOST R IEC 449-96 UDC 696.6:006.354 Group E08 ELECTRICAL BUILDINGS voltage range GCS 27020, 29020 OKS 3402 Effective date 1/1/1997 Preface 1. Prepared and submitted to the Technical Committee for Standardization TC 337 "Electrical residential and public buildings." 2. Adopted and put into operation the Decree of the State Standard of Russia July 10, 1996 № 445. 3. This standard is the authentic text of the International Standard IEC 449-73 "The voltage range of electrical installations of buildings" with Amendment number 1 (1979). 4. First introduced. Introduction This standard provides for the use of international standard IEC 449-73 "The voltage range of electrical installations of buildings". Electrical Code and in particular the regulation of protection against electric shock are determined by the voltage used. Since it is impossible, and there is no need to consider separately each value of applied voltage, the IEC standards for certain types of electrical and electronic devices, establishes requirements that are common to certain voltage ranges. For electrical installations of buildings that are subject to the requirements of a set of international standards IEC 364 "Electrical installation of buildings, apply the requirements of IEC 449-73 (taking into account changes № 1), which has two voltage range. I refer to a range of voltage electrical installations, in which protection against electric shock is ensured for the given conditions, the supply voltage or for which the supply voltage is limited for operational reasons (the installation of communication, signaling, control, etc.). II refer to a range of supply voltage electrical appliances, industrial electrical installations, electrical installations used for utilities, trading companies, etc. In this range includes all the voltage used in the distribution networks of general purpose. IEC 449-73 provides the ability to change certain requirements within the specified voltage range, ie in the relevant standards can be set additional restrictions for certain electrical (electrical devices) or for specific cases of their application (eg, welding, electroplating, etc.). It is assumed that these changes may relate to individual requirements. IEC 449-73 prepared by Technical Committee IEC 364 "Electrical installation of buildings" and is used as a basis and reference for the classification voltage ranges used not only in electrical installations of buildings, but also in other cases. 1. Scope This standard applies to electrical installations of buildings: the AC frequency of 60 Hz at rated voltages up to 1000 inclusive. and DC with rated voltages up to 1500 inclusive. The standard establishes electrical voltage ranges of buildings which are intended for use in conjunction with the regulated in the rules for Electrical building, and can also be used to develop technical requirements for specific electrical equipment. Note. The question of extending the scope of the standard for electrical AC frequencies St. 60 Hz is pending. 2. The definitions in this standard, the following terms. 2.1. Rated voltage - the voltage, for whom the electrical installation (or part thereof). Notes. 1. The actual voltage may differ from the nominal voltage within tolerances. 2. Voltage under transient conditions, due, for example, switches, and short-term fluctuations in voltage due to forced mode, as well as short-circuit in a power line, do not take into account. 2.2. Grounded system - a system in which one point (usually the neutral) is directly connected to the grounding device without deliberately switched resistor. 2.3. Isolated or poorly grounded system - a system in which no point is grounded or at a single point, as a rule, neutral (in the AC system) or the midpoint (in direct current systems) is connected to ground via limiting resistor. 3. Ranges of AC voltage ranges of AC voltage, whereby electrical installations are classified according to their rated voltage, are shown in Table 1: for grounding systems (see 2.2) specified operating voltage between a phase conductor and ground and between phase conductors, for isolated or poorly grounded systems (see 2.3) specified operating voltage between the phases. Table 1 - Range volts alternating current ranges grounded system of isolated or poorly grounded system * Voltage phase to ground voltage between the phases of voltage between phases is 50 IU ? U ? U ? 50 50 II 50 < U ≤ 600 50 < U ≤ 1000 120 < U ≤ 1000 U — номинальное напряжение электроустановки в вольтах. Примечание. Возможно установление других граничных значений в особых случаях. * В системах с распределенной нейтралью (нейтраль выведена в электроустановку) электрооборудование, включаемое между фазой и нейтралью, выбирают таким образом, чтобы его изоляция соответствовала напряжению между фазами. 4. Диапазоны напряжения постоянного тока Диапазоны напряжения постоянного тока, согласно которым электроустановки классифицируются в зависимости от их номинального напряжения, приведены в таблице 2: для заземленных систем (см. 2.2) указаны значения напряжения между полюсом и землей, а также между полюсами; для изолированных или неэффективно заземленных систем (см. 2.3) указаны значения напряжения между полюсами. Таблица 2 — Диапазоны напряжения постоянного тока В вольтах Диапазоны Заземленные системы Изолированные или неэффективно заземленные системы * Напряжение между полюсом и землей Напряжение между полюсами Напряжение между полюсами I U ≤ 120 U ≤ 120 U ≤ 120 II 120 < U ≤ 900 120 < U ≤ 1500 120 < U ≤ 1500 U — номинальное напряжение электроустановки в вольтах. Примечания: 1.Указанные в таблице 2 значения относятся как к напряжениям постоянного, так и выпрямленного постоянного тока. 2. Возможно установление других граничных значений в особых случаях. * В системах с распределенным средним проводником (средний проводник выведен в электроустановку) электрооборудование, включаемое между полюсом и средним проводником, выбирают таким образом, чтобы его изоляция соответствовала напряжению между полюсами. Опубликовано 26.06.2008 ГОСТы по теме "Электрика, освещение, системы безопасности" ГОСТ 15597-82 Светильники для производственных зданий. Общие технические условия ГОСТ 2.702-75 Единая система конструкторской документации. Правила выполнения электрических схем ГОСТ 2.752-71 Единая система конструкторской документации. Обозначения условные графические в схемах. Устройства телемеханики ГОСТ 2.755-87 Единая система конструкторской документации. Обозначения условные графические в электрических схемах. Устройства коммутационные и контактные соединения ГОСТ 2.756-76* Единая система конструкторской документации. Обозначения условные графические в схемах. Воспринимающая часть электромеханических устройств ГОСТ 2.757-81* Единая система конструкторской документации. Обозначения условные графические в схемах. Элементы коммутационного поля коммутационных систем ГОСТ 2.758-81 Единая система конструкторской документации. Обозначения условные графические в схемах. Сигнальная техника ГОСТ 2.762-85* Единая система конструкторской документации. Обозначения условные графические в электрических схемах. Частоты и диапазоны частот для систем передачи ГОСТ 2.763-85* Единая система конструкторской документации. Обозначения условные графические в электрических схемах. Устройства с импульсно-кодовой модуляцией ГОСТ 2.764-86 Единая система конструкторской документации. Обозначения условные графические в электрических схемах. Интегральные оптоэлектронные элементы индикации ГОСТ 2.768-90 Единая система конструкторской документации. Обозначения условные графические в схемах.
No comments:
Post a Comment