Monday, October 17, 2011

GOST 15597-82 Fixtures for industrial buildings. General specifications

GOST 15597-82 UDC 628.94:006.354 Group E83 INTERSTATE STANDARD LAMPS FOR INDUSTRIAL BUILDINGS GENERAL SPECIFICATIONS Luminaires for industrial buildings. General specifications ISS 29.140.40 OKP 34 6110 Effective date 01.01.1984 MEDIA INFORMATION 1. Developed and submitted by the Ministry of Electrical Industry of the USSR 2. Approved and put into effect by Decision of the USSR State Committee on Standards of 06.10.82 № 3899 3. The standard is fully consistent ST SEV 3892-82 4. INSTEAD GOST 15597-70 5. REFERENCE normative and technical documents Designation NTD, which was referenced paragraph number GOST 2.601-95 GOST 12.2.007.0-75 1.2 1.3.1 1.4.7 GOST 7397.0-89 GOST 15150-69 1.4.1, 5.2, 5.3 GOST 16809-88 04/01/1914 GOST 16962-71 GOST 17516-72 04.01.1913 1.4.2 GOST 17557-88 GOST 17677-82 1.4.9 Chapeau, 1.2.1, 1.2.7, 2.1, 3.1, 4.1, 5.1, 6.1 GOST 19348 GOST 23216-78 -82 1.1 5.2 6. Limitations on the duration from the protocol № 3-93 of the Interstate Council for Standardization, Metrology and Certification (ISC 05.06.1993) 7. EDITION (February 2003) with Amendments number 1, 2, approved in September 1983, October 1987 (ICS 1-84, 1-89) This Standard applies to luminaires with incandescent lamps and discharge lamps for lighting industrial buildings rooms and similar agricultural purpose, made for the needs of the economy and for export. The standard does not apply to fittings for installation in hazardous locations, indoor lighting vehicles, lamps with individual power supplies to mines and pits. Fixtures must meet the requirements of GOST 17677 and the requirements set forth in the relevant sections of this standard. (Revised edition, Alt. № 2). 1. SPECIFICATIONS 1.1. Fixtures shall be made in accordance with the requirements of this standard and technical specifications for specific types of lamps or groups of technical documentation, duly approved. Lamps for lighting of premises for agricultural purposes in addition must meet the requirements of GOST 19348. (Revised edition, Alt. № 2). 1.2. Lighting requirements. 1.2.1. Light distribution class and the types of curves of intensity lamps for general lighting should comply with GOST 17677 and specified in the technical specifications for specific types of lighting and / or groups. (Revised edition, Alt. № 2). 1.2.2. Local lighting fixtures should be reflective of neprosvechivayuschih materials to ensure the security angle of not less than 30 °: - in all meridional planes - for Circular lamps - in a plane perpendicular to the plane of symmetry - for lamps with a single plane of symmetry, with the magnitude of the protective angle symmetry plane is not normalized - in the transverse plane - for fixtures with two planes of symmetry. Allowed the lamps to be installed just below the horizontal plane at the level of a security angle is not less than 10 °. 1.2.3. General lighting fixtures should be in the lower hemisphere protective angle of not less than 15 °: - in any meridional plane - for Circular lamps - in the longitudinal and transverse, or only in the transverse plane - for fixtures with two planes of symmetry. Allowed to produce lamps for general lighting with protective angle of less than 15 ° and without a protective angle with the conditions of their use in the technical specifications for specific types of lamps or groups. (Revised edition, Alt. № 1, 2). 1.2.4. In general lighting fixtures with top outlets, luminous body of the lamp should be situated below these holes. 1.2.5. Restricted area and brightness values ??of the overall brightness of the lamps is not standardized. 1.2.6. The illumination of the working surface, created local lighting fixtures shall be not less than 300 lux, and fittings for the implementation of visual artworks low accuracy - at least 150 lux. The dimensions of the illuminated surface, the height of lamps and higher levels of illumination should be specified in the technical specifications for lighting of specific types or groups. 1.2.7. Luminaire efficiency of general lighting, except for joint ventures with a ventilation system or air conditioning should not be less than indicated in the table. 1. Luminaire efficiency, combined with a ventilation system and air conditioning systems should be as specified in Table. 1 for light distribution classes P and O. efficiency lamps for general lighting with fluorescent lamps and shielding grid, which creates a security angle only in one plane, shall not be less than 5% greater than that given in Table. 1. May decrease efficiency of no more than 5% for fixtures: - with two or more discharge lamps - with curly fluorescent bulbs - embedded - with protective netting. With the simultaneous presence of several of these factors decrease the total efficiency of the rated value is allowed no more than 10%. 1.2.6, 1.2.7. (Revised edition, Alt. № 2). Table 1: Light distribution class meets GOST 17677 Description reflector protective (or defensive conditioned), the angle in the lower hemisphere efficiency,%, no less, no optical and shielding elements with transparent or embossed with a protective glass lens

No comments:

Post a Comment