The most common mistake of plastering work, indeed, for the saddest result of plastering work: peeling, cracking plaster and change the geometry of space, due to the thick layer of plaster. These "rake" hit each season, repair and finishing works . We do not aim at such short material to talk about all the problems and defects that arise during plastering. However, we would like to draw your attention to the most common flaws and defects in the plaster. Tips for application of plaster when plastering walls of brick at a temperature ambient 23 ° C and above the surface before applying the solution to moisten. Enhanced and high quality plaster should be performed on the beacons, whose thickness should be equal to the thickness of the plaster coating without nakryvochnyh layer. When the device-layer coating of the surface should flatten immediately after application of the solution, the case of trowels - after his seizure. When the device multilayer plaster coating each layer must be applied after setting the previous (nakryvochnyh layer - after the seizure of the solution). leveling the ground should be performed before setting the solvent. sheets of plaster to stick to the surface of the brick walls of the compounds, respective project, arranged as a brand, size 80x80 mm on at least 10% along the ceiling, floor, corners, vertical plane through a 120-150 mm, in the intervals between them at a distance not exceeding 400 mm along the vertical edges - a continuous strip. Sheets to wooden bases should be fastened with nails with large heads. stucco installation of plaster products must be carried out after setting and drying of the plaster base. Architectural details on the front need to be consolidated for A built-in wall reinforcement, previously protected from corrosion. Specifications plastering robot Allowable thickness single layer of plaster, mm: the application of all types of solutions, except for gypsum - and 20 of plaster solutions - up to 15 measuring at least 5 measurements at 70-100 m2 of surface coatings or in one room, a smaller area in the field identified by continuous visual inspection, magazine work may thickness of each layer in the multilayer device renders without polymer additives, mm: scratch coat on the stone, brick, concrete surfaces - to 5 scratch coat on the wooden surfaces (including the thickness drann) - 9 out of the soil cement mortars - to 5 of calcareous soil, lime-plaster solutions - to 7 nakryvochnyh layer of plaster coating - up to 2 nakryvochnyh layer of decorative finishes - to 7 measuring at least 5 measurements at 70-100 m2 of surface coatings or in one room, a smaller area in the field identified by continuous visual inspection, the magazine works do you repair a panel, a monolithic or brick house in any way with the help of an architect, designer, superintendent, foreman or directly from the masters to fathom, the sag of the surface: floors, walls and ceilings. This and only this will show what is their curvature, slope and swings . These measurements will enable to calculate the flow of the material chosen and determine the complexity, time and cost of the work.
No comments:
Post a Comment